parent
4ad1073c6e
commit
20dd4f25d5
|
|
@ -59,6 +59,7 @@ preflight:
|
||||||
# If you need to check the parity use the `update_xml` preflight.
|
# If you need to check the parity use the `update_xml` preflight.
|
||||||
# KiCad 6 introduced `warnings` they are currently counted be the `unconnected` counter of KiBot.
|
# KiCad 6 introduced `warnings` they are currently counted be the `unconnected` counter of KiBot.
|
||||||
# This will change in the future.
|
# This will change in the future.
|
||||||
|
# If you use DRC exclusions please consult the `drc_exclusions_workaround` global option.
|
||||||
run_drc: true
|
run_drc: true
|
||||||
# [boolean=false] Runs the ERC (Electrical Rules Check). To ensure the schematic is electrically correct.
|
# [boolean=false] Runs the ERC (Electrical Rules Check). To ensure the schematic is electrically correct.
|
||||||
# The report file name is controlled by the global output pattern (%i=erc %x=txt).
|
# The report file name is controlled by the global output pattern (%i=erc %x=txt).
|
||||||
|
|
|
||||||
|
|
@ -84,7 +84,8 @@ Supported preflights
|
||||||
Note that the KiCad 6+ *Test for parity between PCB and schematic* option is not supported. |br|
|
Note that the KiCad 6+ *Test for parity between PCB and schematic* option is not supported. |br|
|
||||||
If you need to check the parity use the `update_xml` preflight. |br|
|
If you need to check the parity use the `update_xml` preflight. |br|
|
||||||
KiCad 6 introduced `warnings` they are currently counted be the `unconnected` counter of KiBot. |br|
|
KiCad 6 introduced `warnings` they are currently counted be the `unconnected` counter of KiBot. |br|
|
||||||
This will change in the future.
|
This will change in the future. |br|
|
||||||
|
If you use DRC exclusions please consult the `drc_exclusions_workaround` global option.
|
||||||
- **run_erc**: :index:`: <pair: preflights; run_erc>` [boolean=false] Runs the ERC (Electrical Rules Check). To ensure the schematic is electrically correct.
|
- **run_erc**: :index:`: <pair: preflights; run_erc>` [boolean=false] Runs the ERC (Electrical Rules Check). To ensure the schematic is electrically correct.
|
||||||
The report file name is controlled by the global output pattern (%i=erc %x=txt).
|
The report file name is controlled by the global output pattern (%i=erc %x=txt).
|
||||||
- **sch_replace**: :index:`: <pair: preflights; sch_replace>` [dict] Replaces tags in the schematic. I.e. to insert the git hash or last revision date.
|
- **sch_replace**: :index:`: <pair: preflights; sch_replace>` [dict] Replaces tags in the schematic. I.e. to insert the git hash or last revision date.
|
||||||
|
|
|
||||||
|
|
@ -30,7 +30,8 @@ class Run_DRC(BasePreFlight): # noqa: F821
|
||||||
Note that the KiCad 6+ *Test for parity between PCB and schematic* option is not supported.
|
Note that the KiCad 6+ *Test for parity between PCB and schematic* option is not supported.
|
||||||
If you need to check the parity use the `update_xml` preflight.
|
If you need to check the parity use the `update_xml` preflight.
|
||||||
KiCad 6 introduced `warnings` they are currently counted be the `unconnected` counter of KiBot.
|
KiCad 6 introduced `warnings` they are currently counted be the `unconnected` counter of KiBot.
|
||||||
This will change in the future """
|
This will change in the future.
|
||||||
|
If you use DRC exclusions please consult the `drc_exclusions_workaround` global option """
|
||||||
def __init__(self, name, value):
|
def __init__(self, name, value):
|
||||||
super().__init__(name, value)
|
super().__init__(name, value)
|
||||||
if not isinstance(value, bool):
|
if not isinstance(value, bool):
|
||||||
|
|
|
||||||
Loading…
Reference in New Issue