Added ERC check
This commit is contained in:
parent
7d02012dbc
commit
5a386bdd32
|
|
@ -481,6 +481,9 @@ class CfgYamlReader(CfgReader):
|
|||
if 'run_drc' in pf:
|
||||
cfg.run_drc = pf['run_drc']
|
||||
|
||||
if 'run_erc' in pf:
|
||||
cfg.run_erc = pf['run_erc']
|
||||
|
||||
if 'ignore_unconnected' in pf:
|
||||
cfg.ignore_unconnected = pf['ignore_unconnected']
|
||||
|
||||
|
|
|
|||
|
|
@ -7,8 +7,10 @@ import os
|
|||
from sys import exit
|
||||
import operator
|
||||
from shutil import which
|
||||
from subprocess import call
|
||||
from subprocess import call, run, PIPE
|
||||
import logging
|
||||
from distutils.version import StrictVersion
|
||||
import re
|
||||
|
||||
from . import plot_config as PCfg
|
||||
from . import error
|
||||
|
|
@ -29,6 +31,19 @@ except ImportError:
|
|||
exit(misc.NO_PCBNEW_MODULE)
|
||||
|
||||
|
||||
def check_version(command, version):
|
||||
cmd = [command, '--version']
|
||||
logger.debug('Running: '+str(cmd))
|
||||
result = run(cmd, stdout=PIPE, stderr=PIPE, universal_newlines=True)
|
||||
z=re.match(command+' (\d+\.\d+\.\d+)', result.stdout)
|
||||
if not z:
|
||||
logger.error('Unable to determine '+command+' version:\n'+result.stdout)
|
||||
exit(misc.MISSING_TOOL)
|
||||
res=z.groups()
|
||||
if StrictVersion(res[0]) < StrictVersion(version):
|
||||
logger.error('Wrong version for `'+command+'` ('+res[0]+'), must be '+version+' or newer.')
|
||||
exit(misc.MISSING_TOOL)
|
||||
|
||||
class PlotError(error.KiPlotError):
|
||||
pass
|
||||
|
||||
|
|
@ -97,12 +112,42 @@ class Plotter(object):
|
|||
elif skip == 'run_drc':
|
||||
self.cfg.run_drc = False
|
||||
logger.debug('Skipping run_drc')
|
||||
elif skip == 'run_erc':
|
||||
self.cfg.run_erc = False
|
||||
logger.debug('Skipping run_erc')
|
||||
else:
|
||||
logger.error('Unknown action to skip: '+skip)
|
||||
exit(misc.EXIT_BAD_ARGS)
|
||||
if self.cfg.run_erc:
|
||||
self._run_erc(brd_file)
|
||||
if self.cfg.run_drc:
|
||||
self._run_drc(brd_file, self.cfg.ignore_unconnected, self.cfg.check_zone_fills)
|
||||
|
||||
def _run_erc(self, brd_file):
|
||||
if which('eeschema_do') is None:
|
||||
logger.error('No `eeschema_do` command found.\n'
|
||||
'Please install it, visit: https://github.com/INTI-CMNB/kicad-automation-scripts')
|
||||
exit(misc.MISSING_TOOL)
|
||||
check_version('eeschema_do','1.1.1')
|
||||
sch_file = os.path.splitext(brd_file)[0] + '.sch'
|
||||
if not os.path.isfile(sch_file):
|
||||
logger.error('Missing schematic file: ' + sch_file)
|
||||
exit(misc.NO_SCH_FILE)
|
||||
cmd = ['eeschema_do', 'run_erc', sch_file, '.']
|
||||
# If we are in verbose mode enable debug in the child
|
||||
if logger.getEffectiveLevel() <= logging.DEBUG:
|
||||
cmd.insert(1, '-vv')
|
||||
cmd.insert(1, '-r')
|
||||
logger.info('- Running the ERC')
|
||||
logger.debug('Executing: '+str(cmd))
|
||||
ret = call(cmd)
|
||||
if ret:
|
||||
if ret < 0:
|
||||
logger.error('ERC errors: %d', -ret)
|
||||
else:
|
||||
logger.error('ERC returned %d', ret)
|
||||
exit(misc.ERC_ERROR)
|
||||
|
||||
def _run_drc(self, brd_file, ignore_unconnected, check_zone_fills):
|
||||
if which('pcbnew_run_drc') is None:
|
||||
logger.error('No `pcbnew_run_drc` command found.\n'
|
||||
|
|
|
|||
|
|
@ -10,5 +10,7 @@ DRC_ERROR = 5
|
|||
EXIT_BAD_ARGS = 6
|
||||
EXIT_BAD_CONFIG = 7
|
||||
NO_PCB_FILE = 8
|
||||
NO_SCH_FILE = 9
|
||||
ERC_ERROR = 10
|
||||
|
||||
|
||||
|
|
|
|||
|
|
@ -464,6 +464,7 @@ class PlotConfig(object):
|
|||
self.check_zone_fills = False
|
||||
self.run_drc = False
|
||||
self.ignore_unconnected = False
|
||||
self.run_erc = False
|
||||
|
||||
def add_output(self, new_op):
|
||||
self._outputs.append(new_op)
|
||||
|
|
|
|||