KiBot/tests/test_plot/test_preflight.py

137 lines
3.5 KiB
Python

"""
Tests for the preflight options
We test:
- ERC
- DRC
- ignore_unconnected
- error
- filter
- XML update
For debug information use:
pytest-3 --log-cli-level debug
"""
import os
import sys
import logging
# Look for the 'utils' module from where the script is running
prev_dir = os.path.dirname(os.path.dirname(os.path.abspath(__file__)))
if prev_dir not in sys.path:
sys.path.insert(0, prev_dir)
# Utils import
from utils import context
from kibot.misc import (DRC_ERROR, ERC_ERROR, BOM_ERROR, CORRUPTED_PCB, CORRUPTED_SCH)
def test_erc_1(test_dir):
prj = 'bom'
ctx = context.TestContext(test_dir, 'ERC', prj, 'erc', '')
ctx.run()
# Check all outputs are there
ctx.expect_out_file(prj+'-erc.txt')
ctx.clean_up()
def test_erc_fail_1(test_dir):
""" Using an SCH with ERC errors """
prj = 'fail-erc'
ctx = context.TestContext(test_dir, 'ERCFail1', prj, 'erc', '')
ctx.run(ERC_ERROR)
# Check all outputs are there
ctx.expect_out_file(prj+'-erc.txt')
ctx.clean_up()
def test_erc_fail_2(test_dir):
""" Using a dummy SCH """
prj = '3Rs'
ctx = context.TestContext(test_dir, 'ERCFail2', prj, 'erc', '')
ctx.run(CORRUPTED_SCH)
ctx.clean_up()
def test_drc_1(test_dir):
prj = 'bom'
ctx = context.TestContext(test_dir, 'DRC', prj, 'drc', '')
ctx.run()
# Check all outputs are there
ctx.expect_out_file(prj+'-drc.txt')
ctx.clean_up()
def test_drc_filter(test_dir):
prj = 'fail-project'
ctx = context.TestContext(test_dir, 'DRC_Filter', prj, 'drc_filter', '')
ctx.run()
# Check all outputs are there
ctx.expect_out_file(prj+'-drc.txt')
ctx.expect_out_file('kibot_errors.filter')
ctx.clean_up()
def test_drc_unco(test_dir):
""" Check we can ignore unconnected nets """
prj = 'warning-project'
ctx = context.TestContext(test_dir, 'DRCUnco', prj, 'drc_unco', '')
ctx.run()
# Check all outputs are there
ctx.expect_out_file(prj+'-drc.txt')
ctx.clean_up()
def test_drc_error(test_dir):
""" Check we catch DRC errors """
prj = 'warning-project'
ctx = context.TestContext(test_dir, 'DRCError', prj, 'drc', '')
ctx.run(DRC_ERROR)
# Check all outputs are there
ctx.expect_out_file(prj+'-drc.txt')
ctx.clean_up()
def test_drc_fail(test_dir):
""" Check we dummy PCB """
prj = 'bom_no_xml'
ctx = context.TestContext(test_dir, 'DRCFail', prj, 'drc', '')
ctx.run(CORRUPTED_PCB)
ctx.clean_up()
def test_drc_time_out(test_dir):
prj = 'bom'
ctx = context.TestContext(test_dir, 'test_drc_time_out', prj, 'drc_time_out', '')
ctx.run(DRC_ERROR)
ctx.search_err('Time out detected')
ctx.search_err('kiauto_wait_start must be integer')
ctx.clean_up()
def test_update_xml(test_dir):
prj = 'bom'
ctx = context.TestContext(test_dir, 'Update_XML', prj, 'update_xml', '')
# The XML should be created where the schematic is located
xml = os.path.abspath(os.path.join(ctx.get_board_dir(), prj+'.xml'))
os.rename(xml, xml+'-bak')
try:
ctx.run()
# Check all outputs are there
# ctx.expect_out_file(prj+'.csv')
assert os.path.isfile(xml)
assert os.path.getsize(xml) > 0
logging.debug(os.path.basename(xml)+' OK')
finally:
os.remove(xml)
os.rename(xml+'-bak', xml)
ctx.clean_up()
def test_update_xml_fail(test_dir):
""" Using a dummy SCH """
prj = '3Rs'
ctx = context.TestContext(test_dir, 'Update_XMLFail', prj, 'update_xml', '')
ctx.run(BOM_ERROR)
ctx.clean_up()